Sale!

Bidirectional Logic Level Converter IIC I + 4 Pieces Male Pin Header 2 + Ultrasonic Module HC-SR05 5

Price range: 2,11 € through 3,52 € Excluding VAT

The Bidirectional Logic Level Converter IIC I + 4 Pieces Male Header Pin 2.54mm + HC-SR05 5-Pin Ultrasonic Sensor Module is a set of components for bidirectional communication between devices with different logic levels and for distance measurement.

  • Bidirectional Logic Level Converter IIC I for bidirectional communication between devices with different logic levels.
  • 4 pieces Male Header Pin 2.54mm for physical connection between components.
  • HC-SR05 5-Pin Ultrasonic Sensor Module for distance measurement.
Shipping, payment and returns
🚚Shipping to Italy: 5.98 € VAT incl. · tracked express courier GLS
📦Available to order: arrives in about 30 days
🎁Free shipping: for orders from 49.90 € (Italy)
🏬Store pickup: free in Rende (CS), Via Giuseppe Verdi 82, Italy
🌍Abroad: European Union 21.50 € + VAT if due · rest of the world 65.00 € · by DHL
💳Payments: Bank Transfer · Carta del Docente · Payment in Store · Credit / Debit Card · PayPal · no cash on delivery
↩️Returns & warranty: 14-day withdrawal for consumers · 24-month legal warranty (12 for businesses)

Domande su questo prodotto? Scrivi a Lana su WhatsApp

⭐ What customers say (feedback received on eBay)

99.4% positive · score 31,572 · on eBay since 2013

«Ottima comunicazione. Grande disponibilià a risolvere i problemi del cliente. Tutto molto bene.»

s***3 · 14/10/2026 · 85C1-UA DC 0-100uA Analogico Panel Meter Amperometro Gauge · eBay

«Conforme alla descrizione. Consegna puntuale.»

a***o · 24/09/2026 · Regolatore di tensione L7805 LM7805 Modulo 5V per Arduino · eBay

More reviews · All feedback on eBay →

Categories: ,

Description

Technical Description

The Bidirectional Logic Level Converter IIC I + 4 Pieces Male Pin Header 2.54mm + HC-SR05 Ultrasonic Module 5 is a set of components useful for bidirectional communication between devices operating at different logic levels. The IIC I converter allows communication between devices operating at 3.3V and 5V. The male pin headers 2.54mm are useful for physical connections between components and the HC-SR05 ultrasonic module is used to measure distance.

The bidirectional IIC I2C level shifter is designed to facilitate communication between devices using different logic levels, ensuring compatibility between Arduino boards and other devices. The pin headers are essential for the physical connection between various circuit components. The ultrasonic sensor HC-SR05 is a distance detector that uses echo detection technology to measure distances.

This kit is suitable for projects requiring bidirectional communication between devices with different logic levels, such as connecting a 3.3V module to a 5V Arduino board. Additionally, it is useful for prototyping and projects that require measuring distances with an ultrasonic sensor.

Key Specifications

Parameter Value
Model Bidirectional Logic Level Converter IIC I + 4 Pieces Male Header Pin 2.54mm + HC-SR05 5 Pin Ultrasonic Sensor Module
Quantity 1
Bidirectional Logic Level Converter IIC I 1
Male Header Pin 2.54mm 4 pieces
HC-SR05 5 Pin Ultrasonic Sensor Module 1
Interface IIC I2C
Operating Voltage 3.3V – 5V
Dimensions N/D (see manufacturer’s datasheet)
Container N/D (see manufacturer’s datasheet)

Installation and Usage

  1. Connect the bidirectional logic level converter IIC I between the IIC bus of the 3.3V device and that of the 5V device.
  2. Use the male header pins to connect the bidirectional converter to the IIC bus and the ultrasonic sensor module.
  3. Power the bidirectional converter and the ultrasonic sensor module with the correct voltage (3.3V or 5V).
  4. Check the connection of the header pins and the compatibility of the logic levels between the devices.
  5. Run a functionality test of the ultrasonic module to verify correct distance measurement.

Compatibility and Requirements

  • The kit is compatible with Arduino boards and other devices that use the IIC I2C protocol.
  • A logic level converter must be used to ensure compatibility between devices operating at different logic levels.
  • To use the ultrasonic module, software or code that interprets signals received from the sensor is required.

Limitations and Important Notes

  • The kit does not include software or code for interpreting signals received from the ultrasonic module.
  • It is necessary to verify the logic level compatibility between devices before connecting the bidirectional converter.
  • The HC-SR05 ultrasonic module has limited precision and is not suitable for measuring extreme distances.
  • Using a bidirectional logic level converter requires attention to avoid damaging devices.

Troubleshooting

The ultrasonic module does not measure distance correctly.
Probable cause: The device’s logic level is not compatible with the module.
Solution: Check and adjust the logic level with a bidirectional converter.

The bidirectional converter does not work correctly.
Probable cause: The pin headers are connected incorrectly.
Solution: Recalculate the pin header connection according to the converter’s documentation.

The ultrasonic module does not respond.
Probable cause: The software or code does not correctly interpret the sensor signals.
Solution: Check and correct the code or software used.

The bidirectional converter generates interference.
Probable cause: The logic levels are not regulated correctly.
Solution: Recalibrate the logic levels between connected devices.

Use cases

Parking Sensor for the Garage
Objective: Measure the distance between the car and the wall to prevent collisions.
What’s needed: HC-SR05 ultrasonic module.
Steps: 1) Connect the ultrasonic module to the bidirectional converter. 2) Power the ultrasonic module. 3) Test the distance measurement.
Expected result: The alarm system warns when the car approaches the wall.

Shop Presence Counter
Objective: Count the number of people entering and exiting the shop.
What’s needed: HC-SR05 ultrasonic module.
Steps: 1) Connect the ultrasonic module to the bidirectional converter. 2) Position the ultrasonic module at the shop entrance. 3) Program the system to count the number of people.
Expected result: The system records the number of people entering and exiting the shop.

Home Security System
Objective: Detect movements inside the house.
What is needed: HC-SR05 ultrasonic module.
Steps: 1) Connect the ultrasonic module to the bidirectional converter. 2) Position the ultrasonic module in the rooms of the house. 3) Program the system to detect movements.
Expected result: The security system alerts of movements inside the house.

Domestic robot prototype
Objective: Create a domestic robot that avoids obstacles.
What is needed: HC-SR05 ultrasonic module.
Steps: 1) Connect the ultrasonic module to the bidirectional converter. 2) Position the ultrasonic module on the robot. 3) Program the robot to avoid obstacles.
Expected result: The domestic robot avoids obstacles during movement.

Access control system
Objective: Control access to a restricted area.
What is needed: HC-SR05 ultrasonic module.
Steps: 1) Connect the ultrasonic module to the bidirectional converter. 2) Position the ultrasonic module at the entrance of the area. 3) Program the system to control access.
Expected result: The access control system allows access only to authorized persons.

Parking Lot Monitoring System
Objective: Monitor the occupancy of a parking lot.
What is needed: HC-SR05 ultrasonic module.
Steps: 1) Connect the ultrasonic module to the bidirectional converter. 2) Position the ultrasonic module in the parking spots. 3) Program the system to monitor occupancy.
Expected result: The monitoring system records the occupancy of the parking spots.

Security System for a Laboratory
Objective: Detect movements inside the laboratory.
What is needed: HC-SR05 ultrasonic module.
Steps: 1) Connect the ultrasonic module to the bidirectional converter. 2) Position the ultrasonic module in the laboratory rooms. 3) Program the system to detect movements.
Expected result: The security system alerts of movements inside the laboratory.

Access control system for an office
Objective: Control access to a restricted area.
What is needed: HC-SR05 ultrasonic module.
Steps: 1) Connect the ultrasonic module to the bidirectional converter. 2) Position the ultrasonic module at the office entrance. 3) Program the system to control access.
Expected result: The access control system allows access only to authorized persons.

In the package

  • 1 Kit Bidirectional Level Logic Converter IIC I + 4 Male Pin Header Pieces 2 + HC-SR05 Ultrasonic Module 5

Complete the project

Technical FAQs

What is the operating voltage range of the bidirectional IIC I logic level converter?
The operating voltage range of the bidirectional IIC I logic level converter is from 3.3V to 5V.

How can I connect the HC-SR05 ultrasonic module to the bidirectional IIC I logic level converter?
To connect the HC-SR05 ultrasonic module to the bidirectional logic level converter IIC I, it is necessary to use the pin headers to connect the module to the converter and ensure the compatibility of the logic levels between the devices.

What are the limitations of the HC-SR05 ultrasonic module?
The HC-SR05 ultrasonic module has limited precision and is not suitable for measuring extreme distances. Additionally, it does not include software or code for interpreting signals received from the sensor.

What are the steps for the first test of the HC-SR05 ultrasonic module?
For the first test of the HC-SR05 ultrasonic module, it is necessary to connect it to the bidirectional logic level converter IIC I, power it with the correct voltage, and test the distance measurement.

Reviews

There are no reviews yet.

Be the first to review “Bidirectional Logic Level Converter IIC I + 4 Pieces Male Pin Header 2 + Ultrasonic Module HC-SR05 5”

Your email address will not be published. Required fields are marked *