Description
Technical Description
The YF-S201 Water Flow Sensor Flussometer 1-30L/min + G1/2 Solenoid Valve 12V Norm + Type K Thermocouple Temperature Sensor kit is a set of components usable to measure water flow and monitor temperature. The YF-S201 flow sensor detects water flow in a range of 1-30 liters per minute, while the G1/2 solenoid valve is activatable with a voltage of 12V and opens normally. The type K thermocouple monitors the water temperature.
The YF-S201 flow sensor is designed for use in water flow monitoring applications, such as irrigation systems or water consumption control. The G1/2 solenoid valve can be used to control water flow in response to signals from the sensor or a control system. The type K thermocouple provides temperature data on the water, useful for applications requiring heat monitoring.
This kit consists of three components: a water flow sensor, an electronic control unit, and a temperature sensor. Each component is designed to interact with the others to provide a complete water flow monitoring and control system.
Key Specifications
| Parameter | Value |
| Flow Sensor Model | YF-S201 |
| Flow Range | 1-30L/min |
| Operating Voltage | 5-24VDC |
| Solenoid Valve Model | G1/2 |
| Solenoid Valve Voltage | 12V |
| Thermocouple Model | Type K |
| Thermocouple Wire | 1M |
| Quantity | 1 set |
Installation and Usage
- Connect the flow sensor YF-S201 to the control system using the provided wires.
- Connect the solenoid valve G1/2 to the electronic control system, ensuring the power supply voltage is 12V.
- Connect the type K thermocouple to the electronic control system using the provided wire.
- Check that all connectors are securely connected.
- Perform a system functionality test to verify that all components are operational.
Compatibility and Requirements
- The flow sensor YF-S201 is compatible with Arduino and Raspberry Pi electronic control systems.
- The solenoid valve G1/2 can be used with electronic control systems that provide a 12V power supply.
- The type K thermocouple is compatible with temperature reading systems such as Arduino and Raspberry Pi.
Important Limits and Notes
- The YF-S201 flow sensor is not designed to work with viscous or non-inert fluids.
- The G1/2 solenoid valve is designed to work with water and similar liquids, not with gases or other fluids.
- The type K thermocouple is not designed for extreme temperatures or corrosive fluids.
- The system is not designed for pressure control or liquid level control applications.
Troubleshooting
The flow sensor does not emit a signal.
Probable cause: Incorrect sensor connection.
Solution: Check that all connectors are securely connected and that the supply voltage is correct.
The solenoid valve does not open.
Probable cause: Insufficient supply voltage.
Solution: Check that the supply voltage is 12V.
The temperature read by the thermocouple is incorrect.
Probable cause: Damaged thermocouple lead.
Solution: Check the integrity of the thermocouple lead and replace it if necessary.
The system does not respond to commands.
Probable cause: Control interface not configured correctly.
Solution: Check the control interface configuration and recalibrate if necessary.
Use cases
Irrigation control system
Objective: Control water flow and temperature for an automatic irrigation system.
What’s needed: Flow sensor, solenoid valve, thermocouple.
Steps: 1) Install the flow sensor. 2) Connect the solenoid valve to the control system. 3) Install the thermocouple to monitor temperature.
Expected result: The irrigation system functions correctly, monitoring water flow and temperature.
Water consumption control system
Objective: Monitor water flow and temperature to control water consumption.
Needed: Flow sensor, solenoid valve, thermocouple.
Steps: 1) Install the flow sensor. 2) Connect the solenoid valve to the control system. 3) Install the thermocouple to monitor temperature.
Expected result: The water consumption control system works correctly, monitoring water flow and temperature.
Aquarium control system
Objective: Regulate water flow and monitor temperature for an aquarium.
Needed: Flow sensor, solenoid valve, thermocouple.
Steps: 1) Install the flow sensor. 2) Connect the solenoid valve to the control system. 3) Install the thermocouple to monitor temperature.
Expected result: The aquarium control system works correctly, regulating water flow and monitoring temperature.
Swimming pool control system
Objective: Regulate the water flow and monitor the temperature for a swimming pool.
What’s needed: Flow sensor, solenoid valve, thermocouple.
Steps: 1) Install the flow sensor. 2) Connect the solenoid valve to the control system. 3) Install the thermocouple to monitor the temperature.
Expected result: The swimming pool control system works correctly, regulating the water flow and monitoring the temperature.
Fountain Control System
Objective: Regulate the water flow and monitor the temperature for a fountain.
What’s needed: Flow sensor, solenoid valve, thermocouple.
Steps: 1) Install the flow sensor. 2) Connect the solenoid valve to the control system. 3) Install the thermocouple to monitor the temperature.
Expected result: The fountain control system works correctly, regulating the water flow and monitoring the temperature.
Air Conditioning Control System
Objective: Regulate water flow and monitor temperature for an air conditioning system.
What’s needed: Flow sensor, solenoid valve, thermocouple.
Steps: 1) Install the flow sensor. 2) Connect the solenoid valve to the control system. 3) Install the thermocouple to monitor temperature.
Expected result: The air conditioning control system functions correctly, regulating water flow and monitoring temperature.
Heating Control System
Objective: Regulate water flow and monitor temperature for a heating system.
What’s needed: Flow sensor, solenoid valve, thermocouple.
Steps: 1) Install the flow sensor. 2) Connect the solenoid valve to the control system. 3) Install the thermocouple to monitor temperature.
Expected outcome: The heating control system functions correctly, regulating the water flow and monitoring the temperature.
Hot water control system
Objective: Regulate the water flow and monitor the temperature for a hot water system.
What’s needed: Flow sensor, solenoid valve, thermocouple.
Steps: 1) Install the flow sensor. 2) Connect the solenoid valve to the control system. 3) Install the thermocouple to monitor the temperature.
Expected outcome: The hot water control system functions correctly, regulating the water flow and monitoring the temperature.
In the package
- 1 set
Complete the project
- Water Flow Sensor Flow Meter YF-S201 1-30L/min 5-24VDC: For a more complete control system, it is recommended to add a liquid level detection module.
Technical FAQs
The flow sensor does not emit a signal?
Check that the power supply voltage is correct and that all connectors are securely connected.
The solenoid valve does not open?
Check that the power supply voltage is 12V.
The temperature read from the thermocouple is incorrect?
Check the integrity of the thermocouple wire and replace it if necessary.
The system does not respond to commands?
Check the control interface configuration and recalibrate if necessary.





Reviews